Premier Gold 'Ex' Certified Sensors

Features
Single-gas types for Hydrocarbon gases or Carbon Dioxide.
Measurement ranges - 0-5% & 0-100% Volume (for Hydrocarbons, a reference calibration gas, e.g. Propane, is used to pre-calibrate the sensors - this must be specified when ordering).
Operating voltage 3 to 5 volts dc, nominal current = 80mA.
Wide operating temperature range of -20 to +50 deg. C.
Output format options - Digital, Analogue or Pellistor Replacement.
Instantly converts existing compatible pellistor-based instruments to infrared.
Sensors can be factory configured to customer specifications.
User configurable via a configuration unit available from Dynament.
Internal 'Flash' memory enables firmware updates via the configuration unit.
Industry standard size - 20mm diameter x 16.6mm high (excluding pins).
3-pin (pellistor replacement) or 5-pin versions available.
Optional replaceable, self-adhesive micro porous 14 micron filter.
Note - Infrared sensors cannot be used to detect Hydrogen gas.
These single-gas sensors contain all the necessary optics, electronics and firmware to provide a linearized, temperature compensated output. The sensors provide equipment designers with a fast track route to introduce the latest infrared technology for detection of gas without the requirement for any specialist knowledge.
They are contained in an Ex d stainless steel housing and are hazardous area certified to IECEx, ATEX and UL standards. The IECEx and ATEX certification also includes Group I (Mining) certification (I M1, Ex db+ia I Ma). Certification Details.
The sensors can be used to measure either Hydrocarbon gases or Carbon Dioxide, depending upon the sensor type, within a wide range of commercial and industrial applications.
The standard measurement ranges that are available for Hydrocarbons are 0-5% and 0-100% volume. The sensors are pre-calibrated using a Hydrocarbon reference gas such as Propane - this must be specified when ordering.
In addition, the High Resolution Methane Sensor provides measurement of Methane over the full range of 0 to 100% volume with a resolution of 0.01 % for 0-10% methane and 0.1% for 10-100% volume.
The standard measurement ranges that are available for Carbon Dioxide are from 0-500ppm up to 0-5% volume and 0-100% volume.
If you have a requirement for an alternative calibration gas or non-standard measurement range then please contact us and we will be please to assist you with your application.
A separately available Configuration Unit enables users to customise certain parameters within the sensor in order to suit their particular requirements.
High Resolution Methane Types
ORDER CODE |
DESCRIPTION |
MSH-P/HR/3/B/N + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 3-Pins, Bridge Output, Negative Supply |
MSH-P/HR/3/B/P + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 3-Pins, Bridge Output, Positive Supply |
MSH-P/HR/3/V/N + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 3-Pins, Voltage Output, Negative Supply |
MSH-P/HR/3/V/P + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 3-Pins, Voltage Output, Positive Supply |
MSH-P/HR/5/B/N + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 5-Pins, Bridge Output, Negative Supply |
MSH-P/HR/5/B/P + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 5-Pins, Bridge Output, Positive Supply |
MSH-P/HR/5/V/N + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 5-Pins, Voltage Output, Negative Supply |
MSH-P/HR/5/V/P + Configuration Options - See Below |
Premier High Resolution Methane Sensor, Certified 5-Pins, Voltage Output, Positive Supply |
Hydrocarbon Types
ORDER CODE |
DESCRIPTION |
MSH-P/HC/3/B/N + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 3-Pins, Bridge Output, Negative Supply |
MSH-P/HC/3/B/P + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 3-Pins, Bridge Output, Positive Supply |
MSH-P/HC/3/V/N + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 3-Pins, Voltage Output, Negative Supply |
MSH-P/HC/3/V/P + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 3-Pins, Voltage Output, Positive Supply |
MSH-P/HC/5/B/N + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 5-Pins, Bridge Output, Negative Supply |
MSH-P/HC/5/B/P + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 5-Pins, Bridge Output, Positive Supply |
MSH-P/HC/5/V/N + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 5-Pins, Voltage Output, Negative Supply |
MSH-P/HC/5/V/P + Configuration Options - See Below |
Premier Hydrocarbon Sensor, Certified 5-Pins, Voltage Output, Positive Supply |
Higher Hydrocarbon Types
ORDER CODE |
DESCRIPTION |
MSH-P/HHC/3/B/N + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 3-Pins, Bridge Output, Negative Supply |
MSH-P/HHC/3/B/P + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 3-Pins, Bridge Output, Positive Supply |
MSH-P/HHC/3/V/N + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 3-Pins, Voltage Output, Negative Supply |
MSH-P/HHC/3/V/P + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 3-Pins, Voltage Output, Positive Supply |
MSH-P/HHC/5/B/N + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 5-Pins, Bridge Output, Negative Supply |
MSH-P/HHC/5/B/P + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 5-Pins, Bridge Output, Positive Supply |
MSH-P/HHC/5/V/N + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 5-Pins, Voltage Output, Negative Supply |
MSH-P/HHC/5/V/P + Configuration Options - See Below |
Premier Higher Hydrocarbon Sensor, Certified 5-Pins, Voltage Output, Positive Supply |
A replaceable, self-adhesive microporous PTFE filter can be fitted to any of the above sensors by adding a suffix /F to the above order codes.
Configuration Options
In addition to the above order codes, the following configuration options should be provided when ordering:-
The Hydrocarbon reference calibration gas (e.g. Methane, Propane etc).
Measurement range/s.
Output voltage for zero.
Output voltage for span
Rising or falling output voltage with increasing gas level (for "Bridge" outputs).
Sensitivity e.g. 100 mV = 100 % volume CH4 for "Bridge" outputs, 0.4 – 2.4V = 100% volume methane for "Voltage" output sensors.
Communication speed – 38,400 baud (default), specify alternative rate if required.
Carbon Dioxide Types
ORDER CODE |
DESCRIPTION |
MSH-P/CO2/5/V/P + Configuration Options - See Below |
Premier 0 - 5% Vol. Carbon Dioxide Sensor, Certified 5-Pin Version, Voltage Analogue Output, Positive Supply |
MSH-P/CO2/5/V/N + Configuration Options - See Below |
Premier 0 - 5% Vol. Carbon Dioxide Sensor, Certified 5-Pin Version, Voltage Analogue Output, Negative Supply |
MSH-P/CO2/3/B/P + Configuration Options - See Below |
Premier 0 - 5% Vol. Carbon Dioxide Sensor, Certified 3-Pin Version, Bridge Output, Positive Supply |
MSH-P/CO2/3/B/N + Configuration Options - See Below |
Premier 0 - 5% Vol. Carbon Dioxide Sensor, Certified 3-Pin Version, Bridge Output, Negative Supply |
MSH-P/HCO2/5/V/P + Configuration Options - See Below |
Premier 0 - 100% Vol. Carbon Dioxide Sensor, Certified 5-Pin Version, Voltage Analogue Output, Positive Supply |
MSH-P/HCO2/5/V/N + Configuration Options - See Below |
Premier 0 - 100% Vol. Carbon Dioxide Sensor, Certified 5-Pin Version, Voltage Analogue Output, Negative Supply |
MSH-P/HCO2/3/B/P + Configuration Options - See Below |
Premier 0 - 100% Vol. Carbon Dioxide Sensor, Certified 3-Pin Version, Bridge Output, Positive Supply |
MSH-P/HCO2/3/B/N + Configuration Options - See Below |
Premier 0 - 100% Vol. Carbon Dioxide Sensor, Certified 3-Pin Version, Bridge Output, Negative Supply |
A replaceable, self-adhesive microporous PTFE filter can be fitted to any of the above sensors by adding a suffix /F to the above order codes.
Configuration Options
In addition to the above order codes, the following configuration options should be provided when ordering:-
Measurement range.
Output voltage for zero.
Output voltage for span
Rising or falling output voltage with increasing gas level (for "Bridge" outputs).
Sensitivity e.g. 100 mV = 100 % volume CO2 for "Bridge" outputs, 0.4 – 2.4V = 100% volume CO2 for "Voltage" output sensors.
Communication speed – 38,400 baud (default), specify alternative rate if required.